Special Techanical Data of Wap5,Wap7 & Wag9

Abbreviation of Three phase locomotives Wap5, Wap7, Wag9 and Wag9H.

nameDetailsnamedetails
ALG:drive control unit- drive inverter and line converter control.ASR:driver converter
ASC:Loco pilot converter control.bL:key switch
BLCP:spring loaded switch for main compressors.BLDJ:Spring loaded switch for main cercuit breaker
BLHO:spring loaded switch for hotel load(not active in wag9)BLPR:switch headlights
BPCS:illuminated puch-button, green for constant speed control.BPFA:illuminated push- button, yellow for acknoledgement all fault messages
BPFL:Illuminated push-button, yellow eemergency flasherlightBPPB:Illuminated push-button, red for parking brake
BPVG:push-button, for green vigilanceBPVR:push-button, illuminated yellow for resetting vigilance
BUR:Auxiliary converterBZ-V-O-F:buzzer for vigilance, over speed and fire
CEL:central electronicsCSC:constat speed control
DDS:diagnostic data unitFLG:vihicle control unit
GTO:gate turn offhB:cubicle auxiliary circuits
hBB:processorhRA:switch cab blower/heater
LSFA:induction lamp, red for train partingLSCE:indication lamp, amber foor over temperature CEL
Special Techanical Data of Wap5,Wap7 & Wag9lSDJ:indication lamp, red for main cercuit breakerLSFI:indication lamp, red for fault message, priority 1
LSHO:Idication lamp, yellow hotel load (not active on wag9)LSP:indication lamp, yellow for wheel slipping
LSVW:indication lamp, yellow for vigilance warningMCB:main circuit breaker
MCE:MICAS-S2 control electronicsMEMOTEL:speed recorder and indicator
MR:machine roomMUB:over voltage protection unit
NSR:line converterpan:pantograph
PCLH:socket hand lampPP:pnuematic panel
SB:cubicle control circuitsSLG:converter control unit
SR:traction converterSS:subsystem
STB:low voltage cubicle controlTE/BE:tractive/ braking effort
UBA:voltmeter battery voltageVCB:vaccum circuit breaker- main circuit breaker
ZBAN:switch banking operationZBV:train bus administrator
ZLC:switch for loco pilot’s lightingZLDA:switch for assistant loco pilot’s desk illumination
ZLDD:switch for loco pilot’s desk illuminationZLFR:switch for marker lights, red
ZLFW:switch for marker lights, whiteZLH:switch for socket hand lamp
ZLI:switch for instrument lightingZPRD:switch for headlights, intensity
ZPT:Spring-loaded switch for pantographZTEL:switch for max traction limitation
zK:dC iink